Phone Number:
+249-183-777-742
Working Hours:
Sun : Thur (7:30 to 16:30)

ARC electrosurgery units


ULTRASONIC

SYSTEM

LIGATION
sealing


SHE SHA SMOKE EVACUATION SYSTEM


BiZZER bipolar scissors and forceps



ARC electrosurgery units

The new generation of electrosurgical devices for monopolar and bipolar electrosurgery with sealing technology. It supports every surgical team thanks to its indication-related set-up options for specific surgical fields.

ARC 400

High-end electrosurgery with glass touch display

ARC 400 combines all available functionalities of electrosurgery with modern operating concepts. It can be used in all surgical disciplines and sets new standards in process safety in hospitals with COMFORT instrument monitoring.

ARC 350

ARC 350 – Universal options

The ARC 350 offers all available electrosurgical functions. In addition to bipolar resection applications in urology and gynaecology and LIGATION sealing of vessels, additional programs provide reproducible results for specific indications (e.g. neurosurgery or cardiothoracic surgery).

ARC 303

Powerful basis for electrosurgery

The ARC 303 is a solid basic equipment for many standard surgical procedures thanks to the possibility to connect two monopolar instruments and one bipolar instrument and power of 300W.

ARC 100

ARC 100 – Monopolar and bipolar electrosurgery in a compact solution

The ARC 100, with one bipolar and one monopolar instrument connection, is the compact solution that is best equipped for all the requirements of both outpatient surgery and minor procedures.

ARC PLUS for ARC 400 / 350

Stirring Plus
ARC PLUS is used as an additional device for ARC 400 and ARC 350 for argon-assisted electrosurgery.

Intended use:
ARC PLUS is used in conjunction with the BOWA RF generator for cutting and coagulation in open and endoscopic argon-supported surgery.

ARC PLUS for ARC 250 / 303

Stirring Plus
ARC PLUS is used as an additional device for ARC 303 and ARC 250 for argon-assisted electrosurgery.

Intended use:
ARC PLUS is used in conjunction with the BOWA RF generator for cutting and coagulation in open and endoscopic argon-supported surgery.


ultrasonic system

The LOTUS Series 4 ultrasonic surgical system and its accessories are indicated for soft tissue surgical incisions when bleeding control and minimal thermal injury are important.
The Lotus Series 4 ultrasonic surgical system and accessories may be used as an adjunct to or substitute for electrosurgery, laser surgery and traditional scalpels in general, gynaecological and thoracic surgery, and involvement of orthopaedic structures (such as a hip joint).

LOTUS LG4 – The powerful torsional ultrasonic system

LOTUS Plug’n Play concept comprises ease of use and compact, lightweight construction of the generator. LG4 generator has three power levels, an innovative power display as well as automatic instrument recognition. The LG4 is optionally activated by handpiece or foot switch.

Lotus Dissecting Shears Handpiece & Transducer

LOTUS dissecting shears were specifically designed for rapid and precise haemostatic tissue preparation. The thin curved shears have focussed recesses and enable accurate dissection at the desired location.

Lotus Accessories

The foot switch is used to activate the LOTUS ultrasonic system. The LOTUS CART is applied as an equipment trolley. The Lotus reprocessing basket with lid is the practical solution for cleaning and sterilising, sterile storage and transport of the Lotus transducer. Transport trunk for a LOTUS LG4.


LIGATION sealing

BOWA LIGATION enables the permanent closure of vessels and tissue bundles with reusable instruments.

The ligation instruments are also suitable for traditional bipolar coagulation
The ligation instruments are intended for use in the bipolar mode ‘LIGATION’
Their use is linked to the ligation programs of the BOWA ARC generators.

NightKNIFE + LIGATOR set & CASE

The ligation instruments are used for sealing arteries, veins and vascularised tissue structures as part of laparoscopic and open application in the fields of gynaecology, urology, general surgery and other surgical disciplines while using RF electrical current and mechanical pressure

ERGO 310D laparoscopic ligation instrument

ERGO 310D – standard for laparoscopic LIGATION. The 5 mm single-use sealing instrument ERGO 310D combined with the BOWA ARC 350 and ARC 400 generators is the perfect system for laparoscopic procedures.

TissueSeal PLUS COMFORT

The ligation instruments are used for sealing arteries, veins and vascularised tissue structures for open application in the fields of gynaecology, urology, general surgery and other surgical disciplines while using RF electrical current and mechanical pressure.

SHE SHA smoke evacuation system

SHE SHA – BOWA’s surgical smoke evacuation system – is designed to evacuate and filter the surgical smoke and aero sols gene rated during the use of surgical equipment for tissue dissection, for example during the use of lasers, electrosurgical systems and ultrasonic devices.

SHE SHA surgical smoke evacuation comes with a powerful vacuum suction motor that is extremely low­ noise in operation and enables a range of flow rates. Surgical smoke is pumped through the vacuum tube into the filter of the SHE SHA surgical smoke evacuator where it is processed through a series of filter layers. SHE SHA uses a single disposable filter, which makes removal and installation easier when changing filters. The filter is fully contained to protect staff from any contamination during filter changes.


SHE SHA smoke evacuation unit

Smoke free in the OR.
Intended use: The quiet and powerful BOWA smoke evacuation system is used to extract smoke, aerosols and hazardous gases that may be produced during laser and electrosurgical procedures.

SHE SHA filter

35 hours smoke-free activation.
The SHE SHA filter with an integrated pre-filter, a ULPA and activated carbon optimises the filtering of electrosurgical smoke, thus helping to improve the air quality in the operating room

SHE SHA hose

10 Pcs per pack.
The sterile single-use hoses are supplied ready to use and can be connected universally to smoke evacuation systems.

SHE SHA handles, length adjustable

10 Pcs per pack.
Greater flexibility. The length of the handle is flexible and can be rotated 360°, allowing surgical smoke to be extracted directly from the source.

SHE SHA handles

10 Pcs per pack.
The sterile single-use handles are supplied ready to use and can be connected universally to smoke evacuation systems.

SHE SHA pre-filter

50 Pcs per pack.
The pre-filter is used tor protect against physical contact with the main filter and is optionally used to supplement the main filter.

BiZZER bipolar scissors and forceps

SHE SHA – BOWA’s surgical smoke evacuation system – is designed to evacuate and filter the surgical smoke and aero sols gene rated during the use of surgical equipment for tissue dissection, for example during the use of lasers, electrosurgical systems and ultrasonic devices.

SHE SHA surgical smoke evacuation comes with a powerful vacuum suction motor that is extremely low­ noise in operation and enables a range of flow rates. Surgical smoke is pumped through the vacuum tube into the filter of the SHE SHA surgical smoke evacuator where it is processed through a series of filter layers. SHE SHA uses a single disposable filter, which makes removal and installation easier when changing filters. The filter is fully contained to protect staff from any contamination during filter changes.


Bipolar forceps

The standard coagulation forceps for the use of safe bipolar technology have a voltage-stable safety coating.

Bipolar NON-Stick forceps with flat grip

New generation of NON-Stick gold forceps. The tried and true NON-Stick gold forceps have specially designed tips with very good thermal properties, providing optimal non-stick performance.

Bipolar NON-Stick forceps with rounded grip

The new rounded grip enables ergonomic and precise rotation of the forceps in the tightest of spaces. These forceps also feature the proven NON-Stick technology.

Monopolar forceps without connector

Protection against glove breakdown.
The high electric safety coating reliably protects against glove breakdown with indirect coagulation.

BiZZER bipolar scissors COMFORT

The bipolar BiZZER scissors allow highly precise surgical work with thin precision tips. A special non-stick coating allows clean work free of adhesions. The COMFORT version with integrated RFID chip allows Plug’n’Play with BOWA COMFORT generators and seamless tracking of use.

Monopolar forceps with connector

The monopolar forceps enable a safe transfer of RF current.
Intended use: Monopolar forceps are used for electrosurgical coagulation.

We use cookies
Cookie preferences
Below you may find information about the purposes for which we and our partners use cookies and process data. You can exercise your preferences for processing, and/or see details on our partners' websites.
Analytical cookies Disable all
Functional cookies
Other cookies
We use cookies to personalize content and ads, to provide social media features and to analyze our traffic. Learn more about our cookie policy.
Change preferences Accept all
Cookies